Product Data Sheet
Safety Data Sheet
How to Use
SURFACE PREPARATION
Surfaces to be
coated must be free of dust, mildew, mold, dirt, grease, loose paint, oil, glue
size, calcimine, wax, soap and other surface contamination. Clean mold stained
surfaces with Advanced Peroxide Cleaner, or use an EPA registered antimicrobial
disinfectant cleaner such as IAQ 2000, IAQ 2500, ShockWave or ShockWave RTU.
Patch irregularities with vinyl patching paste or an appropriate patching
compound. IAQ 6100 is self-priming over bare sheetrock, composition board,
ceiling tile and concrete.
WALLBOARD,
SHEETROCK, GYPSUM BOARD
Joint cement should
be sanded smooth, but avoid abrading the paper.
FERROUS METAL
Clean, then prime
with IAQ 4000 rust inhibiting direct-to-metal primer.
WOOD
Seal knots and
stains with IAQ 5000 stain-blocking primer.
MASONRY BLOCK
Apply one coat of
IAQ 3000 block filler if a denser surface is desired.
APPLICATION TOOLS
Apply IAQ 6100 with
brush, roller or airless spray equipment.
Brush: Synthetic,
nylon or polyester bristle
Roller: Synthetic
fiber 3/8” nap or longer
Spray Settings
Pressure: 2000-2800 P.S.I. Tips: .015 to .019 tips
PRODUCT APPLICATION
IAQ 6100 is supplied
ready to use, but can be thinned sparingly with water (up to 1/2 pint water per
gallon) for proper application consistency if necessary. Apply IAQ 6100
generously and uniformly by brush, roller, or airless spray. Apply one coat of
IAQ 6100 and ensure that the nished
surface is properly sealed. To ensure that the finished surface is properly
sealed, two-coats may be required on some porous surfaces.
COVERAGE
Smooth Surfaces-
350-600 sq. ft. per gallon
Porous Surfaces-
250-300 sq. ft. per gallon
DRYING TIME
@ 70°F 50% R.H
To Touch – 1 Hour
Recoat – 4-8 Hours
CLEANUP
Clean tools and
drippings with warm soapy water before Fiberlock IAQ 6100 dries. Dispose of all
waste according to all existing local, state and federal regulations.
PRECAUTIONS
Store in a dry place
at temperatures between 40°F (4.5°C) and 90°F. (32°C). Stir thoroughly. Do not
mix with any other coatings, solvents or colors in oil. The IAQ 6100 coating is
resistant to mold only on the surface of the coating. No mold resistance claim
is made other than to the coating itself. The use of this product does not
protect users or others against food-borne or disease-causing bacteria,
viruses, germs or other disease-causing organisms. Do not apply when air or
surface temperature is below 50°F, or when drying conditions are poor or when
surfaces are above a 15% moisture level content. Use adequate ventilation
during application. When applying with a sprayer, wear a NIOSH approved
respirator with any R, P, N or HE filter. For interior use only.